TEMPERATURE RANGE: OPERATING 100C --- 400C
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
EFFICIENCY: 68% TYPICAL, AT FULL LOAD
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
OVER LOAD PROTECTION: 130 +/- 20%
OVER VOLTAGE PROTECTION: +5V (5.6V ~ 6.6V), 3.3V (3.6V ~ 4.2V)
SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V
EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
SAFETY: UL 1950, CSA 22.2 NO/ 950, TUV IEC 950
REMOTE ON / OFF CONTROL
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL
DISABLE / ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE.
COOLING: ONE 40mm DC FAN
|