Input Range: 90 ~ 264Vac (RMS), Full Range Input Frequency: 47 ~ 63Hz Input Current: Max 8.5A (RMS) @ 110Vac, 4.0A (RMS) @ 220Vac Inrush Current:80A Max@ 100~240Vac Cold start
· Temperature Range: Operating: 0°C ~ +50°C on full load; storage & shipping: -40°C ~ +70°C · Humidity: 5-85% on operating,5-95% on storage · Dielectric Withstand: Primary frame ground 1800V AC for 3 second · Efficiency: Min 65% @ 100% Load & 72% @ 50% load · Rise time: Less than 70msec · Hold-up Time: 17ms minimum at nominal input voltage · Power Good Signal: Power on delay time5 ~ 400ms, off delay 1ms minimum (TTL and CMOS compatible) · Leakage Current: Less than 3.5mA at 264Vac, 50Hz · MTBF: 100,000 hours on maximum load at +25°C · Dimensions (LxWxH): 300mm*101mm*84.4mm /11.8 x 4x3.3 inch
Output Voltage TMinimum LoadT TNormal LoadT TMaximum LoadT TLoad Reg.T TRipple & NoiseT T+3.3VT T0.5AT T12AT T24AT T± 5%T T50mV P-PT T+5VT T0.5AT T12.5AT T25AT T± 5%T T50mV P-PT T+12V1T T0.5AT T8AT T16AT T± 5%T T120mV P-PT T+12V2T T0.5AT T8AT T16AT T± 5%T T120mV P-PT T+12V3T T1.0AT T8AT T16AT T± 5%T T120mV P-PT T-12VT T0.0AT T0.25AT T0.5AT T± 10%T T120mV P-PT T-5VT T0.0AT T0.1AT T0.2AT T± 10%T T120mV P-PT T+5VsbT T0.0AT T1.0AT T2.0AT T± 5%T T50mV P-PT *+3.3V and +5V total output not exceed 150W *Maximum combined current for the 12V outputs shall be 42A. * Total output for this subject power supply is620W
· Complied with ATX12V standard · Active Power Factor Correction (PFC) meet EN61000-3-2 · High efficiency and reliability · Remote ON/OFF function · Internal 12V DC fan included · Low noise and ripple · Output over voltage, short circuit, and over current protection · 100% Hi-pot, ATE, and burn-in tested · Re-settable power shut down · Complies with FCC part 15 subpart J class B 115Vac operation, and CISPR 22 class B at 230Vac operation · Approved by UL/CUL60950-1, CCC, TUV EN60950 -1, CB report ,FCC,EMC
620 Watts 1+1, 2U Hot-Swap Redundant Switching Power Supply
|