EMACS 1U 400W Redundant Power Supply

$455.00

Compare
SKU: M1S2-5400V4H Category:

Description

Features



  • Temperature range: operating 0�C~40�C, storage -20�C~80�C
  • Hold up time: 16mS min. at full load & 115 input voltage
  • Dielectric withstand: Input/Output 1500 VAC for 1 min., input to frame ground 1500 VAC for 1 min. 
  • Efficiency: 84% / 85% MAX. typical at full load
  • Power good signal: on delay 100mS to 500mS off delay 1Ms
  • Over power protection: 110-150% max
  • Over voltage protection: +5V->5.8~6.9V, +3.3V->3.9~4.6V, +12V->13.9~16.4V
  • Short circuit protection: +12V, -12V, +3.3V, +5V, +5VSB
  • EMI: FCC CLASS A, CISPR 22 CLASS A 
  • Safety: meet UL60950, CSA 22.2 NO.60950-1-03 1ST Edition, TUV IEC 60950-1, CCC 
  • Warning method: LED, BUZZER, TTL SIGNAL
  • Meet IEC-1000-3-2 CLASS D (Active PFC)
  • Hot-swappable/hot pluggable redundancy function
  • Cooling: One 40mm DC fans (module)
  • AC inlet in each module

* The Power Supply is for chassis assembly only and is not allowed to be operated as stand-alone component. Final assembly has to comply with corresponding EMC and safety-regulations. 


Best Solution for



  • Server
  • Workstation
  • Storage system

AC Input Spec



  • Voltage: 90-264VAC full range
  • Frequency: 47-63HZ
  • Input current: 3A (RMS) for high range input voltage, 6A (RMS) for low range input voltage 
  • Inrush current: 20A max. for 132 VAC per module 40A max for 264 VAC per module

DC Output Spec















































Output Voltage


Output Current Min.


Output Current Max.


Regulation Load


Regulation Line


Output Ripple & Noise Max.[P-P]


+5V


1


25


�5%


�1%


50mV


+12V


2


33


�5%


�1%


120mV


-12V


0


0.8


�5%


�1%


120mV


+3.3V


1


25


�5%


�1%


50mV


+5VSB


0.1


3.5


�5%


�1%


50mV

Additional information

Weight 9.00 lbs
Dimension

355.00 x 106.00 x 41.30 (mm) / 13.98 x 4.17 x 1.63 (inch)

Manufacturer

EMACS