INPUT CHARACTERISTICS: VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY: 47 ~ 63 HZ INPUT CURRENT: 10.0 A ( RMS ) FOR 115VAC 6.0 A ( RMS ) FOR 230VAC INRUSH CURRENT: 60.0A MAX. FOR 115 VAC 80.0A MAX. FOR 230 VAC |
OUTPUT CHARACTERISTICS:
OUTPUT
VOLTAGE |
OUTPUT CURRENT |
REGULATION |
OUTPUT RIPPLE & NOISE MAX. [P-P] |
MIN.[A] |
MAX.[A] |
LOAD |
LINE |
+5V |
3.5 |
25.0 |
� 5% |
 �1% |
50mV |
+12V |
2.0 |
40.0 |
� 5% |
 �1% |
120mV |
       +5V |
    0.05 |
      0.5 |
      � 5% |
 �1% |
       120mV |
-12V |
    0.0 |
0.5 |
� 5% |
 �1% |
120mV |
+3.3V |
1.0 |
20.0 |
� 5% |
�1% |
50mV |
+5VSB |
    0.1 |
      2.0 |
+5% |
 �1% |
50mV |
SPECIFICATION:
* TEMPERATURE RANGE: OPERATING 00C – 400C* HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95% * REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS *HOLD UP TIME G16mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE *DIELECTRIC WITHSTANDGINPUT/OUTPUT 1500 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND *EFFICIENCYG65% TYPICAL AAT FULL LOAD *POWER GOOD SIGNALGON DELAY 100mS TO 500mSAOFF DELAY 1mS * OVERLOAD PROTECTIONG110 150% MAX *OVER VOLTAGE PROTECTIONG+5V�5.7V 6.5V , +3.3V�3.7V4.1V , +12V�12.8V~13.9V *SHORT CIRCUIT PROTECTIONG+5VB-5VB+12VB-12VB+3.3V *EMI NOISE FILTER : FCC CLASS B, CISPR22 CLASS B *SAFETY : UL 1950, CSA 22.2 NO 950, TUV IEC 950 *REMOTE ON/OFF CONTROL THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY). AS LOGIC LEVEL IS LOWAOUTPUTS VOLTAGE WERE ENABLE AS LOGIC LEVEL IS HIGHAOUTPUTS VOLTAGE WERE DISABLE. *COOLING : TWO 38mm DC FANS *MEET IEC-1000-3-2 CLASS D |
|