Description
Features
- Temperature range: Operating 0J – 50J, storage -20J – 80J
- Hold up time: 16 ms min at full load & normal input voltage
- Efficiency: 80% typical at 115V, full load
- Power good signal: on delay 100 ms to 500 ms, off delay 1 ms
- EMI Noise filter: FCC CLASS B, CISPR22 CLASS B
- Safety: To meet UL, CUL, TUV, CCC * 3.3V / 5V remote sensing
- Cooling: One 40mm DC FANS
- Active power factor correction meet IEC-1000-3-2 CLASS D
- Connectors:Â rear 24P+4P:520+
Best Solution for
- Server
- Workstation
- Storage System
AC Input Spec
- Voltage:Â 90 ~ 264 VAC full range
- Frequency: 47~63 HZ
- Input current:10.0 A ( RMS ) for 115VAC / 5.0 A ( RMS ) for 230VAC
- Inrush current: 40A max for 115 VAC / 60 A max for 230 VAC
DC Output Spec
Output Voltage | Output Current Min. | Output Current Max. | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] |
+5V | 0.5 | 25 | 5% | 1% | 50mV |
+12V | 2 | 40 | 5% | 1% | 120mV |
-12V | 0 | 0.8 | 5% | 1% | 120mV |
+3.3V | 0.5 | 25 | 5% | 1% | 50mV |
+5VSB | 0.1 | 3.5 | 5% | 1% | 50mV |