Description
Features
- Hold up time: 16ms min at 115AC input; 20ms min at 230 AC input
- Efficiency: typical > 80% at 115V full load
- PFC can reach the target of 95% at 115V/230 VAC full load
- Power good signal: on delay 100ms to 500ms, OFF DELAY 1ms
- Over Power Protection: 110%~160%
- Over voltage protection: +3.3V→3.6~4.3V, +5V→5.6~6.5V, +12V→13.2~15V
- Over current protection: +3.3V→27.5~40A, +5V→27.5~40A, +12V→52.8~72A
- Short circuit protection: +5V, +3.3V, +12V, -12V, +5VSB
- Safety: TO MEET UL, CUL, TUV, CCC
- EMI Noise filter: FCC CLASS B, CISPR22 CLASS B
- Connectors: (20P+A4)+8P
AC Input Specifications
- Voltage: 90~264 VAC FULL RANGE
- Frequency: 47 ~ 63 HZ
- Input current: 10A / 5A AT ANY LOW/HIGH
- Range input voltage
- Inrush current: 40.0A MAX. FOR 115 VAC /
60.0A MAX. FOR 230 VAC (AT 25 degrees ambient cold start)
Output Voltage | Output Current Min | Output Current Max | Regulation Load | Regulation Line | Output Ripple & Noise Max [P-P] |
+5V | 0.5 | 25 | ±5% | ±1% | 60mV |
+12V | 2 | 48 | ±5% | ±1% | 120mV |
-12V | 0 | 0.8 | ±5% | ±1% | 120mV |
+3.3V | 0.5 | 25 | ±5% | ±1% | 60mV |
+5VSB | 0.1 | 3.5 | ±5% | ±1% | 60mV |