Description
Features
- Humidity: operating: 20% – 95%, non-operating: 10% – 95%
- Remarks: 85% is normal condition and 95% is with special coating process
- Hold up time: 16ms min.
- Dielectric withstand: input/output 1500 VAC for 1 min input to frame ground 1500 VAC for 1 min
- Humidity: 95% RH
- Efficiency: 70% typical at 115V at full load
- Power good signal on delay 100ms to 500ms off delay 1ms
- Over load protection: 110-160% max
- Over curren protection: +5V/33A/45A/ +3.3V/33A/45A/+12V/55A/65A
- Over voltage protection: +5V/5.7V/6.5V/+3.3V/3.9V/4.3V
- EMI: FCC class A, CISPR 22 class A
- Meet IEC-1000-3-2 class D (active PFC)
- Built-in fan speed control
- Connectors: 24P+8P+4P (TERMINAL)
Best Solution for:
- Server
- Workstation
- Storage system
- IPC
DC Input Spec
- Voltage: 36 ~ 72VDC full range
- Input current: 17A for 48VDC
- Inrush current: 30A max for 48VDC per module
DC Output Spec
Output Voltage | Min Output Current | Max Output Current | Output Ripple & Noise Max [P-P] |
+5V | 0 | 30 | 50mV |
-5V | 0 | 0.8 | 50mV |
+12V | 2 | 50 | 100mV |
-12V | 0 | 0.8 | 100mV |
+3.3V | 0 | 30 | 50mV |
+5VSB | 0 | 2 | 50mV |
The +12V at 2A than +5Vmax current 20A and +3.3V max current 20A, +5V and +3.3V max 40A
The +12V over 4A than +5V and +3.3V max current 50A
Total power: input voltage at 36VDC ~40VDC the output power 550W (max) 40VDC ~72VDC the output power 600W (max)
noise bandwidth is from DC to 20MHZ