EMACS PS2 600W 1+1 Hot-Swap Redundant EPS-12V Power Supply

Call For Price

Compare
SKU: MRW-6600P Category:

Description


AC INPUT SPEC


VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 Hz
INPUT CURRENT: 10 / 5 A FOR 115 / 230 VAC
INRUSH CURRENT: 80A / 150A MAX. FOR 115 / 230 VAC PER POWER MODULE


OUTPUT CHARACTERISTICS:

























































OUTPUT


VOLTAGE


OUTPUT CURRENT


REGULATION


OUTPUT RIPPLE &
NOISE MAX. [P-P]


MIN.[A]


MAX.[A]


LOAD


LINE


+5V


1


28


+5%,-4%


1%


50mV


+12V


2


45


+5%,-4%


1%


120mV


-5V


0.0


0.8


  5%


1%


120mV


-12V

    0.0

1.0


  5%


1%


120mV


+3.3V


1.0


28


+5%,-3%


1%


50mV


+5VSB

    0.1

      2.5


+5%,-4%


1%


50mV


SPECIFICATION:







* TEMPERATURE RANGE : OPERATING OPERATING: 0 –50 DEGREES
* STORAGE: -20J — 80J
* HUMIDITY:OPERATING:20%-80%, NON-OPERATING:10%-90%
* HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE
* DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE
* INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
* EFFICIENCY: 68% TYPICAL, AT FULL LOAD
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
* OVER LOAD PROTECTION: 110 ~ 150% MAX.
* OVER VOLTAGE PROTECTION: +5V -> 5.7V ~ 6.5V, 3.3V -> 3.9V ~ 4.5V, 12V -> 13.3V~ 14.5V
* OVER CURRENT PROTECTION : 5V, 12V, 3.3V 130% +/- 20% AT FULL LOAD, -5V, -12V SHORT CIRCUIT
* EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
* SAFETY: MEET UL 60950, CSA 22.2 NO/ 60950, TV IEC 60950
* REMOTE ON / OFF CONTROL
* FAULTY ALARM METHODS : LED, BUZZER, TTL SIGNAL
* HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
* BALANCE LOAD SHARING DESIGN
* REMOTE SENSING DESIGN
* ISOLATION: BUILT-IN IN THE POWER MODULE
* MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC )   

Additional information

Weight 15.00 lbs
Dimension

254.00×150.00×84.00 (mm) / 10.00×5.91×3.31 (inch)

Input Voltage

90 ~ 264 VAC FULL RANGE

Output Wattage

600W

Manufacturer

EMACS