Description
Features
- Hold up time: 16ms at max load & normal input voltage
- Efficiency 68% typical (normal line)
- Power good signal: should be asserted high to indicate that +5VDC and +3.3VDC output are above the low voltage thresholds. Compatible signal out with 100ms to 500ms
- Over power protection: The power supply shall shut down output power exceeds 130% to 160%
- Over voltage protection: Standard on +5.0V, set at 6.25VDC 0.75VDC
- Short circuit protection: A short circuit placed between the DC return and the output shall cause no damage and the power supply shall shutdown
- EMI:FCC part 15, subpart B, Class B, EN55022 CISPR22 Class B
- Agency approvals: UL60950, CAN/CSA22.2 No. 60950, TUV(IEC60950)
AC Input
– Voltage: 90~132 or 185~260V, (115/230 auto)
– Frequency: 50/60Hz
- Input current 8A/4A For 115/230VAC
– Inrush current: 60A/80A MAX FOR 115/230
Â
Min Output | Max Output | Load Regulation | Ripple & Noise | |
+5V | 3 | 30 | 5% | 50mV |
+12V | 2 | 15 | 5% | 120mV |
-5V | 0.1 | 0.3 | 5% | 150mV |
-12V | 0.1 | 0.8 | 5% | 150mV |
+3.3V | 1 | 20 | 5% | 50mV |
+5Vsb | 0.1 | 2 | 5% | 50mV |
The combined output power +5V & +3.3V shall not exceed 150W
The total power shall not exceed 300W