Protections: Over Power/Over Voltage/Short Circuits
Current Sharing design on +3.3V, +5V and +12V
Front panel LED to Indicate Power Status
Power Fault Alarm Signals
Alarm Reset
100% burn- in test
Protections Over Power: 110%~150% rated output power Over Voltage: +5V→5.7V~6.5V,+3.3V→3.7V~4.1V,+12V→12.8V~13.9V Short Circuit: Shut down o/p voltage, re-power on to recover
Function Power Good Signal: 100ms~500ms, TTL compatible signal Power Fail Delay: >1msec., TTL compatible signal PS-ON: Power off:PS-ON=2V min.; Power on:PS-ON=0.8V max.
Environmental Operating Temperature: 0˚C to 45˚C Storage Temperature: -20˚C to +70˚C Operating Humidity: 20% to 90%,non-condensing Storage Humidity: 5% to 95%, non-condensing
Safety & EMI/RFI Safety Standards: UL,cUL,TUV,CB EMI/RFI Standards: CISPR22(EN55022) Class A, FCC Part15 Class A Harmonic: EN61000-3-2
Others MTBF: >100,000 hours Coolings: 38x38x28mmx8 DC FANS Dimension(DxWxH): 300x101x166mm
Output
Output Voltage
Output Current
Regulation
Output Ripple & Noise Max.(p-p)
TC-1800RVN4
Min.
Max.
LOAD
LINE
+5V
4A
91A
5%
1%
50mV
+3.3V
4A
70A
5%
1%
50mV
+12V
6A
130A
5%
1%
70mV
-12V
0A
2A
5%
1%
70mV
+5VSB
0.4A
3.5A
5%
1%
50mV
Efficiency
72% Typical at full load
HoldupTime
16m sec. minimum, at full load
REMARKS:
1.Total Max output of +5V AND +3.3V not exceed 580W
2.Power module Total output power not exceed 1800W for TC-1800RVN4.