Description
Features
- Hold up time: 16ms at max load & normal input voltage
- Efficiency: 80& typical (normal line)
- Power good signal: should be asserted high to indicated that +5VDC and +3.3VDC output are above the low voltage thresholds. Compatible signal out with 100ms to 500ms
- Over power protection: the power supply shall shut down output power exceeds 130% to 160%
- Over voltage protection: standard on +5.0V, set at 6.25VDC ± 0.75VDC
- Short circuit protection: a short circuit placed between the DC return and the output shall cause no damage and the power supply shall shutdown
- EMI: FCC part 15, subpart B, Class B, EN55022 CISPR22 Class B
- Agency approvals: UL60950, CAN/CSA22.2 No.60950, TUV(IEC60950)
- Meet EN-6100-3-2 class D (Active PFC)
- Remote On/OFF control: when PS-ON is pulled to TTL low, the DC output is to be enabled. When PS-OFF is pulled to TTL high, the DC output is to disabled.
AC Input
- Input Voltage: 100V-240V (Active PFC/Full Range)
- Input current: 13A
- Inrush current: 65A/125A Max for 115/230
- Input Frequency: 47Hz~63Hz
DC Output
Output Voltage | Min(A) Current | Max(A) Current | Load Reg. | Line Reg. | Ripple & Noise |
+5V | 0.2 | 30 | ±5% | ±1% | 60mV |
+12V1 | 2 | 16 | ±5% | ±1% | 120mV |
+12V2 | 0 | 16 | ±5% | ±1% | 120mV |
+12V3 | 0 | 16 | ±5% | ±1% | 120mV |
+12V4 | 0 | 16 | ±5% | ±1% | 120mV |
-5V | 0 | 0.8 | ±10% | ±1% | 120mV |
-12V | 0 | 1 | ±10% | ±1% | 120mV |
+3.3V | 0.5 | 30 | ±5% | ±1% | 60mV |
+5Vsb | 0 | 3 | ±5% | ±1% | 60mV |
The combined output power +5V & +3.3V shall not exceed 64A
The combined output power +5V & +12V & +3.3V max output 880W
The total power shall not exceed 900W