Description
Introduction
The Infortrend A16F-G2430 SAN-ready subsystem combines cost-effective SATA drives in a high availability 4G FC array. IT managers will find it is an easy-to-use and easy to maintain storage solution for their DAS, Fibre Channel SAN and clustered servers or any application requiring dedicated bandwidth.
Features
- Two (2) FC-4G host channels; transfer rate up to 400MBps per channel
- Accommodates sixteen the latest 3Gbps, SATA-II (3Gbps) disk drives
- ASIC400 architecture that supports hardware RAID 5 and RAID 6 engine
- Market leading I/O performance
- Sustained RAID5 Read/Write at 658/460 MB/sec.
- Sustained RAID6 Read/Write at 651/411 MB/sec.
- Sustained RAID5 Read/Write at 658/460 MB/sec.
- Embedded RAIDWatch software for effortless RAID management
- Windows Server 2003 certified
Specifications
RAID
- Multiple arrays configurable with dedicated or global hot spares
- RAID levels supported: RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
- Online expansion by:
- Adding new drives,
- Copying and replacing drives with drives of larger capacity
- Adding new drives,
- Automatic background rebuilds
- Configurable stripe size and write policy per array
- Intelligent drive handling:
- In degraded mode: skips irreparable blocks to continue rebuild
- In normal operation: data-block verification and repair
Subsystem Components
- Single controller configuration provides full RAID functionalities
- One (1) EonStor enhanced 3U enclosure
- One (1) RAID controller module
- One (1) 512MB DDR RAM DIMM module (pre-installed on the controller modules)
- Two (2) hot-swappable, redundant, 530W power supply units (PSUs)
- Two (2) redundant, dual-fan cooling modules running in high/low speeds
- One (1) optional BBU
- Sixteen (16) hot-swappable drive trays
- Two (2) front handles
Host Interface
- Two (2) FC-4G host channels; backward compatible with 1 or 2G-FC
- Auto-negotiate FC-AL, point-to-point, or switched fabric
- Concurrent I/O commands
- Tagged command queuing up to 256
- Variable stripe size per logical drive
- Optimization setting for random or sequential I/Os
Drive Interface
- Sixteen (16) hot-swappable 3Gbps SATA-II (3Gbps) drive trays that accommodate 1-inch pitch, 3.5-inch SATA-II (3Gbps) or SATA-I disk drives
- Automatic bad-sector reassignment
- Dedicated bandwidth to each connected drive
Management
- Firmware-embedded utility via LCD keypad or RS-232C port
- Host-side SES emulation with pass-through to back-end SES emulation
- VT-100 terminal emulation via RS-232C
- Telnet access via onboard Ethernet port
- 10/100 BaseT Ethernet for out-of-band management
- Two (2) COM ports for local access to firmware-embedded utility and UPS connectivity
- Java-based SANWatch software:
- Graphical user interface,
- Local/remote management; in-band or out-of-band via TCP/IP,
- Centralized management to monitor and administer multiple RAID units on one screen, Secure link over SSL
- Graphical user interface,
- Configuration Client for easy access to the configuration utility screen
- Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
San Management
- Up to 1024 LUNs (if sufficiently large memory is used with the proper settings)
Indicators
- Onboard alarm is triggered when one of the following fails:
- RAID controller module
- Cooling module
- Power supply unit
- Hard drive
- BBU module
- Module status LED indicators:
- Two (2) per drive tray
- Three (3) per LCD panel
- Six (6) per RAID controller module
- One (1) per Fibre port
- Two (2) per Ethernet port
- Two (2) per cooling module
- One (1) per power supply unit
- One (1) per BBU module
- Module failure alert through I2C bus
- Event notifications sent over email, fax, LAN broadcast, SNMP traps, MSN messenger, SMS short messages
- System alerts through Java-based SANWatch manager
Physical
- Two (2) FC ports, each using a short-wavelength adapter
- Two (2) COM ports on the controller module for RS-232C serial port (38400, n, 8, 1) and UPS support
- One (1) 10/100BaseT Ethernet port on the controller module
- Two (2) redundant, hot-swappable power supplies with PFC
- Dimensions: Chassis without handles: 445(W) x 130(H) x 488.2(D) mm (17.5 x 5.1 x 19.2 inches), Chassis with handles: 482.6(W) x 131(H) x 504.3(D) mm (19 x 5.2 x 19.9 inches), Package: 423(H) x 567(W) x 772(D) mm (16.7 x 22.3 x 30.4 inches)
- System weight (w/o drives): Net weight: 28.5kg (62.7 pounds), Gross weight: 30.5kg (67.1)